Jual Panel Metering Cubicle - SM6-24 Schneider Electric

Switch and fuse protection cubicles

1 switchgear: switch-disconnector and earthing switch in an enclosure filled with SF6 and satisfying "sealed pressure system" requirements.
2 busbars: all in the same horizontal plane, thus enabling later switchboard extensions and connection to existing quipment.
3 connection: accessible through front, connection to the lower switch-disconnector and earthing switch terminals (IM cubicles) or the lower fuse-holders (PM and QM cubicles). This compartment is also equipped with an earthing switch downstream from the MV fuses for the protection units.
4 operating mechanism: contains the elements used to operate the switchdisconnector and earthing switch and actuate the corresponding indications (positive break).
5 low voltage: installation of a terminal block (if motor option installed), LV fuses and compact relay devices. If more space is required, an additional enclosure may be added on top of the cubicle. Options: please, refer to the chapter "Characteristics of the functional units".

SF6 circuit breaker cubicles

1 switchgear: disconnector(s) and earthing switch(es), in enclosures filled with SF6 and satisfying "sealed pressure system" requirements.
2 busbars: all in the same horizontal plane, thus enabling later switchboard extensions and connection to existing equipment.
3 connection and switchgear: accessible through front, connection to the downstream terminals of the circuit breaker.
Two circuit breaker offers are possible:
 • SF1: combined with an electronic relay and standard sensors (with or without an auxiliary power supply
 • SFset: autonomous set equipped with an electronic protection system and special sensors (requiring no auxiliary power supply).
4 operating mechanism: contains the elements used to operate the disconnector(s),
the circuit breaker and the earthing switch and actuate the corresponding indications. 
5 low voltage: installation of compact relay devices (Statimax) and test terminal boxes. If more space is required, an additional enclosure may be added on top of the cubicle.

Options: please, refer to the chapter "Characteristics of the functional units".

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot